Sample passport for demonstration. Product, serial number and signatures are illustrative.
Nonius
Sample passport pages for Safety Class 3 equipment under NP-089-15, clause 141
Passportof a vessel with design pressure above 0.05 MPa
Ion exchange filter for special water treatment
When the vessel passes to another owner, the passport goes with it.
General information
Vessel name
Ion exchange filter for special water treatment
Serial number
НС-2025-013
Date of manufacture
2025
Manufacturer
Nonius LLC, design bureau and production
Conformity documents
Conformity assessment under NP-071-18, Rostechnadzor licenses (NP-089-15)
1. Technical characteristics and parameters
Vessel part
Body
Working pressure, MPa
0.8
Design pressure, MPa
1
Hydraulic test pressure, MPa
1.35
Working temperature, °C
60
Design wall temperature, °C
70
Minimum allowable wall temperature under design pressure, °C
−40
Working medium
boric acid solution
Medium group by TR CU 032/2013
2
Corrosion allowance, mm
0
Capacity, m³
4.64
Empty mass, kg
870
Assigned service life, years
30
2. Main parts of the vessel
Part
Qty
Dimensions, mm
Material
Thickness, mm
Shell
1
1,400 × 2,500
08Х18Н10Т
6
Elliptical head, GOST 6533
2
1,400 × 6
08Х18Н10Т
6
3. Nozzles
Mark
Purpose
Nominal size DN
Qty
А
Medium inlet
150
1
Б
Medium outlet
150
1
В
Medium inlet
100
1
Г
Medium outlet
100
1
Д
Vent
50
1
Е
Instruments
50
1
7. Welding and non-destructive testing
Shell welded by automatic submerged arc, root passes by argon arc. Shell and head butt welds radiographed in full; nozzle welds checked by liquid penetrant.
11. Hydraulic test
Hydraulic test pressure, MPa
1.35
Test medium
water
Test medium temperature, °C
5 to 40
Vessel position during the test
vertical
12. Conclusion
The vessel was made in full compliance with GOST 34347-2017, TR CU 032/2013 and the design documents. It passed visual inspection and the hydraulic test at the pressure in section 11 and is fit for service at the parameters stated in this passport.
Chief engineersignature
Head of quality controlsignature
Seal
General arrangement
Dimensions for reference. Nozzle orientation turned into the drawing plane.