Products for the customer's design pressure and temperature, from specification to shipment with documents.
The same data as a table
| Work | Design pressure, MPa | Design wall temperature, °C | Inner diameter, mm |
|---|---|---|---|
| Water loop volume compensator | 2.5 | 200 | 1600 |
| Blowdown aftercooler | 2 | 150 | 600 |
| Ion exchange filter for special water treatment | 1 | 70 | 1400 |
| Sodium loop drain tank | 0.6 | 520 | 2000 |
| Test facility water heater | 8 | 280 | 800 |
| Steam separator | 4.5 | 255 | 1000 |
| Controlled leakage tank | 0.6 | 100 | 2400 |
| Sample cooler | 16 | 300 | 250 |
| Intermediate circuit heat exchanger | 1.6 | 120 | 1000 |
- Materials
- Austenitic steels 08Kh18N10T and 12Kh18N10T, plate up to 50 mm; carbon and low-alloy steels by agreement.
- Rules
- Safety class 3 elements of nuclear plants: NP-089-15, welding to NP-104-18, metal inspection to NP-105-18. Everything else: GOST 34347-2017 and TR CU 032/2013.