Steam separator
Thermal-hydraulic test facility of a research centre, 2023
Ø 1,000 × 1,552 mm1.9 m³4 MPa, 250 °C12Х18Н10Т
Separates moisture from steam ahead of the test section.
- Working pressure
- 4 MPa
- Working temperature
- 250 °C
- Inner diameter
- 1,000 mm
- Working medium
- steam
Task
Steam must be dry ahead of the test section: droplets distort the measurements.
The bureau’s solution
A vertical separator with a louvre dryer at the top and condensate drained from the bottom head.
What the bureau did
- design documents
- manufacture
- tests
Operating conditions
- Design pressure
- 4.5 MPa
- Working pressure
- 4 MPa
- Design wall temperature
- 255 °C
- Working temperature
- 250 °C
- Working medium
- steam
- Rules
- GOST 34347-2017, TR CU 032/2013
Design
- Type
- Vertical vessel
- Inner diameter
- 1,000 mm
- Shell length
- 2,000 mm
- Wall thickness
- 16 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 4.5·1,000 / (2·1·153 − 4.5) = 14.9 mm. With a 1 mm allowance, 16 mm plate was taken. [σ] = 153 MPa for 12Х18Н10Т at 255 °C — GOST 34233.1, table A.3.
- Shell material
- 12Х18Н10Т
- Overall size
- 1,552 × 1,032 × 3,392 mm
- Capacity
- 1.9 m³
- Empty mass
- 1,320 kg
Tests and inspection
- Hydraulic test pressure
- 6.8 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 4.5 · 184 / 153 — GOST 34347, 7.11.3
- Non-destructive testing
- Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds
Product documents
- Passport
- Open for print
- Strength calculation
- in the delivery set
- Operating manual
- in the delivery set
- Metal certificates
- in the delivery set
Lead time
24 weeks from signed specification to shipment
Discuss a similar task
The request starts with a reference to this work; add how your task differs.
Discuss a similar task