Test facility water heater
Thermal-hydraulic test facility of a research centre, 2024
Ø 800 × 5,950 mm7.2 MPa, 270 °C12Х18Н10Т
Heats test section water with steam from the facility boiler.
- Working pressure
- 7.2 MPa
- Working temperature
- 270 °C
- Inner diameter
- 800 mm
- Working medium
- water
Task
The test section needs water at 270 °C and 7.2 MPa, and the heat source is steam from the facility boiler.
The bureau’s solution
A shell-and-tube heater with water in the tubes and steam in the shell; flanged channels allow the tubes to be cleaned.
What the bureau did
- design documents
- manufacture
- tests
Operating conditions
- Design pressure
- 8 MPa
- Working pressure
- 7.2 MPa
- Design wall temperature
- 280 °C
- Working temperature
- 270 °C
- Working medium
- water
- Rules
- GOST 34347-2017, TR CU 032/2013
Design
- Type
- Shell-and-tube heat exchanger
- Inner diameter
- 800 mm
- Shell length
- 4,500 mm
- Wall thickness
- 25 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 8·800 / (2·1·150 − 8) = 21.9 mm. With a 1 mm allowance, 25 mm plate was taken. [σ] = 150 MPa for 12Х18Н10Т at 280 °C — GOST 34233.1, table A.3.
- Shell material
- 12Х18Н10Т
- Overall size
- 5,950 × 1,026 × 1,410 mm
- Empty mass
- 7,200 kg
Tests and inspection
- Hydraulic test pressure
- 12.3 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 8 · 184 / 150 — GOST 34347, 7.11.3
- Non-destructive testing
- Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds
Product documents
- Passport
- Open for print
- Strength calculation
- in the delivery set
- Operating manual
- in the delivery set
- Metal certificates
- in the delivery set
Lead time
32 weeks from signed specification to shipment
Discuss a similar task
The request starts with a reference to this work; add how your task differs.
Discuss a similar task