Blowdown aftercooler
VVER-1200 power unit, 2023
Ø 600 × 7,022 mm1.6 MPa, 130 °C08Х18Н10Т
Cools blowdown water before the special water treatment filters.
- Working pressure
- 1.6 MPa
- Working temperature
- 130 °C
- Inner diameter
- 600 mm
- Working medium
- water
Task
Blowdown water must be cooled from 130 to 50 °C ahead of the ion exchange filters: resin loses capacity when hot.
The bureau’s solution
A shell-and-tube unit with fixed tube sheets and removable channel covers, so tubes are inspected and plugged without cutting the shell.
What the bureau did
- design documents
- manufacture
- tests
Operating conditions
- Design pressure
- 2 MPa
- Working pressure
- 1.6 MPa
- Design wall temperature
- 150 °C
- Working temperature
- 130 °C
- Working medium
- water
- Safety class by NP-001-15
- 3НAssigned by the plant designer and stated in the specification
- Rules
- NP-089-15, NP-104-18, NP-105-18
Design
- Type
- Shell-and-tube heat exchanger
- Inner diameter
- 600 mm
- Shell length
- 6,000 mm
- Wall thickness
- 6 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 2·600 / (2·1·148 − 2) = 4.1 mm. With a 1 mm allowance, 6 mm plate was taken. [σ] = 148 MPa for 08Х18Н10Т at 150 °C — GOST 34233.1, table A.3.
- Shell material
- 08Х18Н10Т
- Overall size
- 7,022 × 744 × 1,162 mm
- Empty mass
- 2,950 kg
Tests and inspection
- Hydraulic test pressure
- 2.85 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 2 · 168 / 148 — GOST 34347, 7.11.3
- Non-destructive testing
- Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds
Product documents
- Passport
- Open for print
- Strength calculation
- in the delivery set
- Operating manual
- in the delivery set
- Metal certificates
- in the delivery set
Lead time
34 weeks from signed specification to shipment
Discuss a similar task
The request starts with a reference to this work; add how your task differs.