Sample cooler

    VVER-1200 power unit, 2025

    Ø 250 × 2,037 mm14 MPa, 290 °C12Х18Н10Т

    Cools coolant samples before analysis.

    Working pressure
    14 MPa
    Working temperature
    290 °C
    Inner diameter
    250 mm
    Working medium
    water

    Task

    Coolant samples at 290 °C and 14 MPa must be cooled to 40 °C right at the sampling point.

    The bureau’s solution

    A small shell-and-tube unit rated for 16 MPa, with the sample in the tubes and service water in the shell.

    What the bureau did

    1. design documents
    2. manufacture
    3. tests

    Operating conditions

    Design pressure
    16 MPa
    Working pressure
    14 MPa
    Design wall temperature
    300 °C
    Working temperature
    290 °C
    Working medium
    water
    Safety class by NP-001-15
    3НAssigned by the plant designer and stated in the specification
    Rules
    NP-089-15, NP-104-18, NP-105-18

    Design

    Type
    Shell-and-tube heat exchanger
    Inner diameter
    250 mm
    Shell length
    1,200 mm
    Wall thickness
    16 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 16·250 / (2·1·148 − 16) = 14.3 mm. With a 1 mm allowance, 16 mm plate was taken. [σ] = 148 MPa for 12Х18Н10Т at 300 °C — GOST 34233.1, table A.3.
    Shell material
    12Х18Н10Т
    Overall size
    2,037 × 372 × 734 mm
    Empty mass
    390 kg

    Tests and inspection

    Hydraulic test pressure
    24.9 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 16 · 184 / 148 — GOST 34347, 7.11.3
    Non-destructive testing
    Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds

    Product documents

    Strength calculation
    in the delivery set
    Operating manual
    in the delivery set
    Metal certificates
    in the delivery set

    Lead time

    18 weeks from signed specification to shipment