Sample cooler
VVER-1200 power unit, 2025
Ø 250 × 2,037 mm14 MPa, 290 °C12Х18Н10Т
Cools coolant samples before analysis.
- Working pressure
- 14 MPa
- Working temperature
- 290 °C
- Inner diameter
- 250 mm
- Working medium
- water
Task
Coolant samples at 290 °C and 14 MPa must be cooled to 40 °C right at the sampling point.
The bureau’s solution
A small shell-and-tube unit rated for 16 MPa, with the sample in the tubes and service water in the shell.
What the bureau did
- design documents
- manufacture
- tests
Operating conditions
- Design pressure
- 16 MPa
- Working pressure
- 14 MPa
- Design wall temperature
- 300 °C
- Working temperature
- 290 °C
- Working medium
- water
- Safety class by NP-001-15
- 3НAssigned by the plant designer and stated in the specification
- Rules
- NP-089-15, NP-104-18, NP-105-18
Design
- Type
- Shell-and-tube heat exchanger
- Inner diameter
- 250 mm
- Shell length
- 1,200 mm
- Wall thickness
- 16 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 16·250 / (2·1·148 − 16) = 14.3 mm. With a 1 mm allowance, 16 mm plate was taken. [σ] = 148 MPa for 12Х18Н10Т at 300 °C — GOST 34233.1, table A.3.
- Shell material
- 12Х18Н10Т
- Overall size
- 2,037 × 372 × 734 mm
- Empty mass
- 390 kg
Tests and inspection
- Hydraulic test pressure
- 24.9 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 16 · 184 / 148 — GOST 34347, 7.11.3
- Non-destructive testing
- Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds
Product documents
- Passport
- Open for print
- Strength calculation
- in the delivery set
- Operating manual
- in the delivery set
- Metal certificates
- in the delivery set
Lead time
18 weeks from signed specification to shipment