Sample passport for demonstration. Product, serial number and signatures are illustrative.
Nonius
Sample pages of a passport in the form of GOST 34347-2017, annex T
Passportof a vessel with design pressure above 0.05 MPa
Water loop volume compensator
When the vessel passes to another owner, the passport goes with it.
General information
Vessel name
Water loop volume compensator
Serial number
НС-2024-011
Date of manufacture
2024
Manufacturer
Nonius LLC, design bureau and production
Conformity documents
Declaration of conformity to TR CU 032/2013
1. Technical characteristics and parameters
Vessel part
Body
Working pressure, MPa
2.2
Design pressure, MPa
2.5
Hydraulic test pressure, MPa
3.6
Working temperature, °C
180
Design wall temperature, °C
200
Minimum allowable wall temperature under design pressure, °C
−40
Working medium
water
Medium group by TR CU 032/2013
2
Corrosion allowance, mm
0
Capacity, m³
9.28
Empty mass, kg
3,440
Maximum mass of working medium, kg
9,280
Assigned service life, years
30
2. Main parts of the vessel
Part
Qty
Dimensions, mm
Material
Thickness, mm
Shell
1
1,600 × 4,000
12Х18Н10Т
14
Elliptical head, GOST 6533
2
1,600 × 14
12Х18Н10Т
14
Saddle support
2
1,400 × 256
09Г2С
12
3. Nozzles
Mark
Purpose
Nominal size DN
Qty
А
Nitrogen feed and vent
150
1
Б
Connection to the loop
150
1
В
Vent
50
1
Г
Drain
50
1
Д
Level gauge
50
1
Л
Manhole
500
1
П
Safety valve
80
1
7. Welding and non-destructive testing
Shell welded by automatic submerged arc, root passes by argon arc. Shell and head butt welds radiographed in full; nozzle welds checked by liquid penetrant.
11. Hydraulic test
Hydraulic test pressure, MPa
3.6
Test medium
water
Test medium temperature, °C
5 to 40
Vessel position during the test
horizontal
12. Conclusion
The vessel was made in full compliance with GOST 34347-2017, TR CU 032/2013 and the design documents. It passed visual inspection and the hydraulic test at the pressure in section 11 and is fit for service at the parameters stated in this passport.
Chief engineersignature
Head of quality controlsignature
Seal
General arrangement
Dimensions for reference. Nozzle orientation turned into the drawing plane.